Storage Tank Bottom Corrosion Mapping

Guided-wave screening of a lap-welded tank floor from the external tank-bottom extension.

Inspection and result

An MsT array mounted on the accessible tank-bottom extension collected data used to map and rank suspect corrosion within the floor.

Measurements at multiple frequencies and complementary wall scans helped distinguish bottom indications from tank-wall responses. The study reports screening and relative severity assessment; confirmation and sizing require suitable follow-up inspection.

Probe on the external tank-bottom extension and reconstructions at 64, 45, and 32 kHz.
Probe on the external tank-bottom extension and reconstructions at 64, 45, and 32 kHz. ASNT 2026, slide 12

Sensors paper · Tank-bottom results

Vinogradov, S.; Akimov, N.; Cobb, A.; Fisher, J. Screening of Corrosion in Storage Tank Walls and Bottoms Using an Array of Guided Wave Magnetostrictive Transducers. Sensors 2026, 26(4), 1253.

Relevant pages
16–17
Figures
Figure 15 shows corrosion maps. Figure 16 ranks the indications.
Section
7.3 — storage tank bottom corrosion

Unmodified article reproduced under Creative Commons Attribution 4.0. Copyright remains with the authors. The summaries on this page were prepared by GNDE.

MTI CONNECT article

Sergey Vinogradov, Nikolay Akimov, Adam Cobb, and Jay Fisher. Corrosion Mapping in Storage Tank Bottoms Using an Array of Guided Wave Magnetostrictive Transducers. MTI CONNECT, 2024, Issue 1.

Figure 5 shows field results from a lap-welded tank bottom scanned from the external plate extension.