CUP Application. Axial and circumferential scans

An axial scan screened for corrosion under two concrete pipe supports. A follow-up circumferential scan mapped the affected area beneath support 2.

Axial and circumferential scan results

ASNT slide 6 showing the probe installations and the axial and circumferential scans at concrete pipe supports.
The axial scan at 128 kHz identifies the suspect region at support 2. The circumferential scan at 180 kHz shows the corrosion cluster beneath the support. ASNT 2026, slide 6.

An 11-segment MsT bracelet scanned axially along the 42-inch OD carbon-steel pipe, which had a 0.4-inch wall. At support 2, an 8 × 8 MsT array scanned around the pipe and located a corrosion cluster approximately 20 inches (0.5 m) from the probe.